Fire protection facade
AF 50EI
Based on the solution, it is possible to construct flat walls of fire resistance class EI 60.




The AF 50EI facade system is used to construct lightweight curtain walls.

Design & functionality
Sheathing seal wrapping around the entire socket for superior tightness.
Lintel-window strips available with EI 60 fire resistance.
The solution is compatible with other Aluron systems.
Profiles and gaskets flushed from the inside of the facade.
Straight-cut transoms to facilitate prefabrication, also for angled connections.
Three drainage levels available.
Easy assembly and prefabrication.
Technical drawings
Section through the mullion

Section through the transom

Temperature distribution

Technical parameters
System characteristics
Width of mullion and transom sections
50 mm
Range of depth of mullion and transom sections
90-320 mm
Glazing range
up to 64 mm
Load bearing capacity of glass
up to 380 kg
Selected technical parameters of the system
Thermal insulation of U facade
from 0,7 W/m2K
Fire resistance
EI 60
Water tightness
class RE 2400 Pa
Wind load resistance
2400 Pa
Safety test
±3600 Pa
Air permeability
class AE 1500 Pa
Impact resistance
class E5/I5
Download files
Product sheet
AF 50EI